- COMPANY
- NEWS
- ABOUT US
- CONTACT US
- WARRANTY & TERMS
- PRODUCTS
- MAIN PRODUCTS
- COLD-PACK LED EMERGENCY DRIVER
- LED EMERGENCY DRIVER
- FLUORESCENT EMERGENCY BALLAST
- MINI EMRGENCY INVERTER
- PARALLELABLE MODULAR INVERTER
- DIMMABLE EMERGENCY LIGHTING CONTROL DEVICE
- LED TEST SWITCH
- LIGHTING
- TECHNOLOGY
- SLIM SIZE
- POWERFUL
- RELIABLE
- DURABLE
- DOWNLOADS
- SELECTION GUIDE
2X18W
- Item No.
- FL02H218-2
- FL02I218-2
- FL02H218-2-H
- FL02J218-2
- GE part number
- 109W1982P005
- 109W1982P006
- 109W1982P007
- 109W1982P008
- Characteristics
- 2x18W Light, Standard Weather (SW)
- 2x18W Light, Emergency Backup, SW
- 2x18W Light, Heater, Cold Weather (CW)
- 2x18W Light, Emergency Backup and Heater, CW
- Lamp type
- Fluorescent Lamp T8 2x18W
- Rated voltage
- 220-240VAC 50/60Hz
- Input power
- 36W
- 42W
- 36W
- 42W
-
- -
- -
- 76W (Heater Works)
- 84W (Heater Works)
- Input current
- 0.19-0.13A
- 0.20-0.14A
- 0.19-0.13A
- 0.20-0.14A
-
- -
- -
- 0.32-0.35 (Heater Works)
- 0.35-0.38 (Heater Works)
- Power factor
- >0.98
- >0.95
- >0.98
- >0.95
- Battery voltage
- /
- 1.8Ah, 4.8V
- /
- 1.8Ah, 4.8V
- Charging time
- /
- 24 hours
- /
- 24 hours
- Discharge time
- /
- >90 minutes
- /
- >90 minutes
- Operation temperature
- -15~50°C
- -15~50°C
- -30~50°C
- -30~50°C
- Survival temperature
- -20~60°C
- -20~60°C
- -40~60°C
- -40~60°C
- Battery life time
- /
- 5 years
- /
- 5 years
- Abnormal protection
- short-circuit Protection with auto-reset
- Applicable standards
- EN60598-1, EN60598-2-1, EN61347-1, EN61347-2-7, EN55015, EN61000-3-2, EN61000-3-3, EN61547, IEC60721-3-3; IEC60721-3-3 class 3C1, class 3Z7 & class 3S1
2X36W
- Item No.
- FL02H236-2
- FL02I236-2
- FL02H236-2-H
- FL02J236-2
- GE part number
- -
- -
- 108W9547P006
108W9547P008
- 108W9547P004
108W9547P005
- Characteristics
- 2x36W Light, Standard,Standard Weather (SW)
- 2x36W Light, Emergency Backup, SW
- 2x36W Light, Heater, Cold Weather (CW)
- 2x36W Light, Emergency Backup and Heater, CW
- Lamp type
- Fluorescent Lamp T8 2x36W
- Input voltage
- 220-240VAC 50/60Hz
- Input power
- 72W
- 75W
- 72W
- 75W
- -
- -
- 112W (Heater Works)
- 115W (Heater Works)
- Input current
- 0.30-0.33A
- 0.31-0.34A
- 0.30-0.33A
- 0.31-0.34A
- -
- -
- 0.47-0.51A (Heater Works)
- 0.48-0.52A (Heater Works)
- Power factor
- >0.98
- >0.95
- >0.98
- >0.95
- Battery voltage
- -
- 1.8Ah, 4.8V
- -
- 1.8Ah, 4.8V
- Charging time
- -
- 24 hours
- -
- 24 hours
- Emergency time
- -
- >90 minutes
- -
- >90 minutes
- Operation temperature
- -15~50°C
- -15~50°C
- -30~50°C
- -30~50°C
- Survival temperature
- -20~60°C
- -20~60°C
- -40~60°C
- -40~60°C
- Battery life time
- -
- 5 years
- -
- 5 years
- Abnormal protection
- short-circuit Protection with auto-reset
- Applicable standards
- EN60598-1, EN60598-2-1, EN61347-1, EN61347-2-7, EN55015, EN61000-3-2, EN61000-3-3, EN61547, IEC60721-3-3; IEC60721-3-3 class 3C1, class 3Z7 & class 3S1